CHORVATANIA

Komunita obyvateľov a sympatizantov obce Chorvátsky Grob

Sinamics s120 active line module

>> Download Sinamics s120 active line module


>> Read Online Sinamics s120 active line module













Siemens AG filexlib. Interface Modules include the required pre-charging input circuit for the Active Line Module, in addition to a Clean Power Filter. These two components are considered to be an integral unit for SINAMICS S120 Cabinet Modules and are supplied together. For a compact configuration, Line Connection Modules up to input currents of 3,200 A are available. SINAMICS S120 ACTIVE LINE MODULE INPUT: 3-PH 380-480V, 50/60HZ OUTPUT: DC 600V, 27A, 16KW FRAME SIZE: BOOKSIZE INTERNE LUFTKUEHLUNG INKL. DRIVE-CLIQ LEITUNG: Price data: Region Specific PriceGroup / Headquarter Price Group: S60 / 7A7: List Price: Show prices: Customer Price: Show prices: Surcharge for Raw Materials: None: Metal Factor: None: Delivery information
Application description Introduction SINAMICS S120 has a modular design, and addresses complex drive tasks in the widest range of industrial applications. A user can select a solution that best corresponds to his specific requirements from a wide variety of components and functions that are harmonized and coordinated with one another.
The modular SINAMICS S120 frequency converter is the modular system for high-performance motion control applications in industrial plant and machinery construction. Flexible, modular drive system for demanding single-axis or multi-axis applications. Skip to main content; Skip to main navigation
Los Active Line Modules se utilizan siempre en combinación con un Active Interface Module. Los Active Interface Modules contienen, además del Clean Power Filter, el circuito de. precarga necesario para el Active Line Module. En SINAMICS S120 Cabinet Modules, ambos componentes se consideran y se suministran. como una unidad conexa.
SINAMICS S120 Einbaugeräte Bauform Chassis; Luftgekühlte Geräte; Power Modules; Active Line Modules; Active Interface Modules; Smart Line Modules; Basic Line Modules; Motor Modules; Montagevorrichtung für Powerblöcke; Flüssigkeitsgekühlte Geräte; Power Modules; Active Line Modules; Active Interface Modules; Basic Line Modules; Motor Modules
Siemens Sinamics S120 Online-Anleitung: Active Line Modules, Beschreibung. 5.3 Active Line Modules 5.3.1 Beschreibung Die Selbstgeführten Ein-/Rückspeiseeinheiten Arbeiten Als Hochsetzsteller Und Erzeugen Eine Geregelte Zwischenkreisspannung, SINAMICS S150 Austausch Der Dc-Sicherungen Im Active Line Module, Motor Module, Baugröße Hx.
SINAMICS S120 booksize Braking Module and the matching external Braking Resistor are required to bring drives to a controlled standstill in the event of a power failure (e.g. emergency retraction or EMERGENCY STOP category 1) or limit the DC link voltage for brief periods of generator operation, e.g. when the regenerative feedback capability of the Line Module is deactivated.
Netzanschaltung und netzseitige Leistungskomponenten Einleitung Zur Anschaltung eines SINAMICS S120 Booksize-Antriebsverbandes an das Versorgungsnetz werden folgende Komponenten verwendet: Netztrenneinrichtung Überstromschutzeinrichtung Netzschütz (optional) Netzfilter (optional) Netzdrossel bzw. bei Active Line Module auch Active Interface Module (immer erforderlich) Die folgenden Netzfilter- und Netzdrosselvarianten stehen zur Verfügung: SINAMICS S120CM cabinet modules. The concept of SINAMICS S120CM enclosed drive cabinet modules is innovative: configure even the most complex multi-motor common DC bus drive line-ups or highest HP multiparallel drives up to over 6,000 Hp (4,500 kW) by combining standard enclosed drive modules Available in designs both to IEC and NEMA standard

Komentár

Komentáre môžu pridávať iba členovia CHORVATANIA.

Pripojte sa k sieti CHORVATANIA

© 2024   Created by Štefan Sládeček.   Používa

Symboly  |  Nahlásiť problém  |  Podmienky služby