CHORVATANIA

Komunita obyvateľov a sympatizantov obce Chorvátsky Grob

Promag 53 user manual

 

 

PROMAG 53 USER MANUAL >> DOWNLOAD LINK

 


PROMAG 53 USER MANUAL >> READ ONLINE

 

 

 

 

 

 

 

 











 

 

Promag 10 Identification Endress+Hauser 7 2.1.2 Nameplate of the sensor A0004374 Fig. 2: Nameplate specifications for the "Promag" sensor (example) 1 Ordering code/serial number: See the specifications on the order confirmation for the meanings of the individual letters and digits. 2 Calibration factor with zero point 3 Nominal diameter Mounting Documents / Manuals / Software. Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10. Check out how Hofbrauhaus Freising samples wastewater with Promag L 400 in a nearly inaccessible shaft. Proline Promag W 400 / 5W4C Versatile standard flowmeter for the water and wastewater Proline Promag 50H, 53H 4 Endress+Hauser Input Measured variableFlow velocity (proportional to induced voltage) Measuring rangesMeasuring ranges for liquids Typically v = 0.01 to 10 m/s (0.03 to 33 ft/s) with the specified accuracy Operable flow rangeOver 1000 : 1 Safety instructions Proline Promag 53 FOUNDATION Fieldbus 4 Endress+Hauser 1 Safety instructions 1.1 Designated use The measuring device described in this Operating Manual is to be used only for measuring the flow rate of conductive fluids in closed pipes. All fluids (including demineralized water) can be metered, provided they have a minimum Proline Promag 50P, 53P Endress+Hauser 3 Function and system design Measuring principle Following Faraday's law of ma gnetic induction, a voltage is induced in a conductor moving through a magnetic field. In the electromagnetic measuring principle, the flowing medium is the moving conductor. Promag E is a streamlined sensor for basic chemical applications. It is the most economical solution for our chemical customers. Combined with the Promag 53 transmitter with touch control, four line display and extended functionality like software options for filling and dosing, electrode cleaning or advanced diagnostics, Promag 53E offers highest accuracy in the most complex and demanding All-Guides Database contains 22 Promag Manuals (44 Devices) for Free Downloading (PDF). Promag Card Reader Manuals 5 Devices / 5 Documents Full list of Promag Card Reader Manuals Promag Clock Manuals 2 Devices / 2 Documents Full list of Promag Clock Manuals Promag Commercial Food Equipment Manuals 12 Devices / 12 Documents An overview of the complete Promag 33 measuring system is shown below. The technical specifications are stamped on the nameplate and contain the following information: Pat. 219,725 UK (EP) Pat. 4,704,908 US Pat. 2084740 UK Pat. 4,382,387 US Order Code: Ser.No.: ENDRESS+HAUSER PROMAG 2X 123456 33FT50-AD1AA12A21F 85-260VAC 50-60Hz EPD/MSÜ ECC 5P-CAL Proline Promag 50W, 53W 4 Endress+Hauser Input Measured variableFlow velocity (proportional to induced voltage) Measuring rangesMeasuring ranges for liquids Typically v = 0.01 to 10 m/s (0.03 to 33 ft/s) with the specified accuracy Operable flow rangeOver 1000 : 1 Input signal Status input (auxiliary input) Translate PDF. Operating Instructions Proline Promag 53 Electromagnetic Flow Measuring System 6 BA047D/06/en/03.05 50097083 Valid as of version: V 2.00.XX (Device software) fBrief operating instructions Proline Promag 53 Brief operating instructions These brief operating instructions show you how to configure the measuring device quickly and PR O nlie P romag 53 1 Safet y inst ruct ions E ndress + Hau ers 7 1 Saetyf instructions 1. 1 Des ignated us e The measuring device described in this Operating Manual is to be used on

Komentár

Komentáre môžu pridávať iba členovia CHORVATANIA.

Pripojte sa k sieti CHORVATANIA

© 2024   Created by Štefan Sládeček.   Používa

Symboly  |  Nahlásiť problém  |  Podmienky služby