Komunita obyvateľov a sympatizantov obce Chorvátsky Grob
By default, Cisco Nexus 5500 switches dynamically reacts to any FEX connectivity changes - they remove any configuration commands for the non-existing interfaces (this happens when FEX is not connected). In turn, this brings the relevant interfaces on the other switch into vPC inconsistent state even though the FEX is still connected to it; Design Choices. Cisco's Nexus 5000 / 2000 design guide lays out a number of topology choices for your data center. Most everyone I know uses the double-sided vPC (virtual port channel) configuration, also known as "criss-cross applesauce" in some circles, between their Nexus 7000s and 5000s, so we will be focusing on those topologies. The reason I ask is because I downloaded the "Cisco_Nexus_9000_Series_NX-OS_Interfaces_Configuration_Guide" full manual and did a search for "fex-fabric" and there was no reference in the manual. My background is with the NS5596UP and the 2248 "Fabric Extender" FEX. a service running to be able to activate the FEX configuration in case of a The Cisco Nexus 2348TQ Fabric Extender (FEX) provides 48 10 GT host port interfaces and up to six 40 GE fabric interfaces in a compact 1-rack-unit (1RU) form factor. This platform, with innovative features and enhanced buffers, is ideally suited for migrating to 10GBASE-T in the network access. Collapse. CISCO N2K-C2248-FAN-B NEXUS 2200 GE FEX FAN REVERSED AIRW Condition. Refurbished. $45.00 We currently have 10 in stock. our technicians will try to guide you through a solution, as it may be due to configuration; If unable to resolve the issue over the phone, Inteleca will provide a replacement, repair the equipment, or issue a full refund Choose Connection for Cisco . Buy a Cisco 10Gb SFP Fabric Extender Transceiver for Nexus 2148T, 2224TF, 2224TP, 2232PP 10GE, 2248TP and get great service and fast delivery. When a device (PC/Server) connected via the 2248, the only thing we are able to do is ping anywhere within the network. We are unable to do /work with any other traffices over that connection like rdp/http/notes ect. If we connect the device direct to the 5548 , it works perfectly alright. Some were saying its about big packet size traffic. This preview shows page 52 - 54 out of 160 pages. 1-12 Cisco Nexus 5000 Series Troubleshooting Guide OL-25300-01Chapter 1 Troubleshooting Layer 2 Switching Issues Registers and Counters Note The show platform fwm info gatos-errors command increments 3 times for a given drop. Other expected drops Queue is full When a queue is full, you need to Cisco's Nexus 5000 / 2000 design guide lays out a number of topology choices for your data center. Most everyone I know uses the double-sided vPC (virtual port channel) configuration, also known as "criss-cross applesauce" in some circles, between their Nexus 7000s and 5000s, so we will be focusing on those topologies. Due to the replication failure, we started to unplug some things. The FEX 2248 in question was unplugged from the second Nexus 5548UP it was connected to. That secondary Nexus 5548UP still had connectivity to the primary Nexus 5548UP and both Nexus 7010's. The problem still happened. Next, we reconnected the FEX 2248 to the secondary Nexus Warranty: 1 Year. The Cisco Nexus 56128P is a wire-rate Layer 2 and Layer 3 switch offering 10 Gigabit Ethernet, unified ports (UP) and 2 expansion slots in a two-rack-unit form factor. It is optimized for 10 Gigabit Ethernet top-of-rack access, C
© 2025 Created by Štefan Sládeček.
Používa
Komentáre môžu pridávať iba členovia CHORVATANIA.
Pripojte sa k sieti CHORVATANIA